Design and Production of Plants for the Refrigeration OEM sector used for the production of Refrigerated Cabinets, domestic Refrigerators, Chillers, fixed and portable air conditioning machines, Refrigerated Counters, New generation heat pumps, refrigerated appliances of various types, etc.

For over 20 years Sinteco has been building this type of plants tailored to the most important Brands in the Home and Commercial Refrigeration sector.

chiller-di-raffreddamento-OEM_Manufacturing-refrigeration-chiller-OEM
Produzione-pompe-di-calore OEM_Manufacturing-heat-pump-OEM
Produzione-Frigoriferi-completi-OEM_Manufacturing-refrigerator-machine-OEM

Design and Production of Plants for the Refrigeration OEM sector used for the production of Refrigerated Cabinets, domestic Refrigerators, Chillers, fixed and portable air conditioning machines, Refrigerated Counters, New generation heat pumps, refrigerated appliances of various types, etc.

For over 20 years Sinteco has been building this type of plants tailored to the most important Brands in the Home and Commercial Refrigeration sector.

The above Plants include:

  • Storage, Transfer, Distribution in low pressure and Injection System in Refrigerant circuits of Refrigerant Gases (such as Isobutane “R600a”, Propane “R290”, R134a, R152a, R407C, R410A, HFO1234yf, R32, and all A2L and A3 gases currently on the market, etc.
  • Sinteco has been an expert in the introduction of flammable gases A3 in the refrigeration sector, since the early 1990s.
  • Storage, Transfer and Distribution in low and high pressure of Blowing gases used in Rigid Expanded Polyurethane Foaming for the realisation of Refrigerator cabinets (such as: Pentane, Cyclopentane, Cyclo/Isopentane, R134a, HFO, Solstice LBA, R245fa, etc.)
  • Storage, Transfer and Distribution in low pressure of Polyol, Isocyanate, Catalysts and Additives.
  • Polyol-Blowing gas Premixing Unit.

Our technology lends itself to both non-flammable and flammable products.

Specifically, in addition to the above:

  • “Safety” systems: Forced air exhaust and gas detection system with control SW in environments where flammable and/or dangerous products are used (Production – Finished product storage warehouses).
  • Flammable/explosive Eexd – Eexi gas detection.
  • Electro-Pneumatic safety command and control systems.
  • Safety Electrical Panels for production process control
  • SW systems with operator interface PLC.

The above Plants include:

  • Storage, Transfer, Distribution in low pressure and Injection System in Refrigerant circuits of Refrigerant Gases (such as Isobutane “R600a”, Propane “R290”, R134a, R152a, R407C, R410A, HFO1234yf, R32, and all A2L and A3 gases currently on the market, etc.
  • Sinteco has been an expert in the introduction of flammable gases A3 in the refrigeration sector, since the early 1990s.
  • Storage, Transfer and Distribution in low and high pressure of Blowing gases used in Rigid Expanded Polyurethane Foaming for the realisation of Refrigerator cabinets (such as: Pentane, Cyclopentane, Cyclo/Isopentane, R134a, HFO, Solstice LBA, R245fa, etc.)
  • Storage, Transfer and Distribution in low pressure of Polyol, Isocyanate, Catalysts and Additives.
  • Polyol-Blowing gas Premixing Unit.
  • Our technology lends itself to both non-flammable and flammable products.

Specifically, in addition to the above:

  • “Safety” systems: Forced air exhaust and gas detection system with control SW in environments where flammable and/or dangerous products are used (Production – Finished product storage warehouses).
  • Flammable/explosive Eexd – Eexi gas detection.
  • Electro-Pneumatic safety command and control systems.
  • Safety Electrical Panels for production process control
  • SW systems with operator interface PLC.

Standardised and certified systems according to:

  • M.D. May 14, 2004 – LPG DEPOSITS (Less than 13mc): Approval of the fire prevention technical rule for the installation and operation of liquefied petroleum gas deposits with a total capacity not exceeding 13 cubic metres (as amended).
  • M.D. October 13, 1994 – LARGE LPG DEPOSITS (Over 13mc): Approval of the fire prevention technical rule for the design, construction, installation and operation of LPG deposits in fixed tanks with a total capacity exceeding 5 mc and/or in mobile containers with a total capacity exceeding 5,000 kg.
  • PED Directive 2014/68/EU on the harmonisation of the laws of the Member States relating to the making available on the market of pressure equipment.
  • ATEX Directive 2017/34/EU concerning the harmonisation of laws in Member States relating to equipment and protective systems intended for use in a potentially explosive atmosphere.
  • Classification of areas in accordance with the “ATEX” regulation.

Contact Sinteco

    COMPANY *

    FULL NAME *

    ADDRESS

    CITY *

    DISTRICT

    COUNTRY *

    E-MAIL ADDRESS *

    TELEPHONE *

    FAX

    ADDRESSEE *

    Privacy art. 7 GDPR 679/2016 (click HERE and read the privacy policy)

    The customer agrees to consent to personal data processing for communication purposes with Sinteco srl

    YESNO

    The customer agrees to the addition of his/her data in Sinteco srl databases for business communication purposes by Sinteco srl

    YESNO

    HOW CAN WE HELP YOU?